Check that the parts of the foam cutter are in good condition and adjust the level regularly. Add enough lubricating oil according to the lubrication regulations, inject saponified oil and water into the working fluid tank, keep it clean, and check whether the pipe joints are firm.
Check whether the connection between the machine tool and the control box is well connected, whether the input signal is consistent with the direction of movement of the traction plate, and adjust the high-frequency pulse power supply.
Check whether the vertical and horizontal strokes of the worktable are flexible, and whether the machine can move back and forth, and move the column to the middle of the double baffle. The limit switch stop should be adjusted within the required range to avoid disconnection when starting. When the column moves to the neutral position, the motor needs to be turned off. Do not turn off the switch when switching.
To avoid inertia, moving the post breaks the molybdenum wire, and even the nut is cordless. After completing the above inspection, you can turn on the machine, install the workpiece, put the workpiece to be cut on the installation table, and fix it with the platen screws.
When cutting the entire cavity, the workpiece and mounting table must not touch the wireframe. When cutting the mold, the molybdenum wire should be installed through the reserved hole on the workpiece before cutting.
The above is a summary of the correct operation process of EPS cutting machine for you, I hope it will help you.